Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lifebreath Error Code Dehumidistat light flashing: Dehumidistat calling, unit on high speed (Hrv)

Updated · by Aurora Star Tech Inc.

Lifebreath error code Dehumidistat light flashing on a hrv means: Dehumidistat calling, unit on high speed. It is also called Lifebreath diagnostic code Dehumidistat light flashing.

Low severityHrvRNC

Homeowner? What Lifebreath code Dehumidistat light flashing means for you

Usually minor Your heating or cooling system is reporting: Dehumidistat calling, unit on high speed. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lifebreath error code Dehumidistat light flashing mean?

On the BC02 or BC03 wall control the dehumidistat light blinks when the house humidity is above the set point. The HRV is forced to high speed ventilation no matter what speed was picked. Normal operation, not a fault.

Applies to: 99-BC02, 99-BC03 wall controls

Common causes of Lifebreath code Dehumidistat light flashing

  • Indoor humidity is above the dehumidistat set point
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lifebreath models that use code Dehumidistat light flashing

RNC5-ES

Other Lifebreath Hrv codes

CodeMeaning
0Fan speed 0 = standby (DXPL02)
Dehumidistat light steadyDehumidistat satisfied
OFFDehumidistat turned off (DXPL02)
Repeater LED flashing greenWireless repeater: medium link
Repeater LED redWireless repeater: no link to main control
Repeater LED solid greenWireless repeater: strong link
Service indicatorMaintenance due (DXPL02)
Timer battery LED redWireless timer battery low

All Lifebreath Hrv error codes →

Lifebreath code Dehumidistat light flashing: homeowner questions

What does Lifebreath code Dehumidistat light flashing mean?

Dehumidistat calling, unit on high speed. On the BC02 or BC03 wall control the dehumidistat light blinks when the house humidity is above the set point. The HRV is forced to high speed ventilation no matter what speed was picked. Normal operation, not a fault.

Is it safe to keep using my heating or cooling system with code Dehumidistat light flashing?

Usually yes. Code Dehumidistat light flashing is normally minor, but if it keeps coming back have it checked.

Can I reset Lifebreath code Dehumidistat light flashing myself?

You can try one reset (power off for 30 seconds, then on). If Lifebreath code Dehumidistat light flashing comes back, the cause is still there and a licensed technician should check it.

Who can fix Lifebreath code Dehumidistat light flashing near me?

Aurora Star Tech Inc. repairs Lifebreath heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Ventilation Controls BC02 / BC03, p. 5-6. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977