Lifebreath Error Code Dehumidistat light flashing: Dehumidistat calling, unit on high speed (Hrv)
Lifebreath error code Dehumidistat light flashing on a hrv means: Dehumidistat calling, unit on high speed. It is also called Lifebreath diagnostic code Dehumidistat light flashing.
Homeowner? What Lifebreath code Dehumidistat light flashing means for you
Usually minor Your heating or cooling system is reporting: Dehumidistat calling, unit on high speed. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Lifebreath error code Dehumidistat light flashing mean?
On the BC02 or BC03 wall control the dehumidistat light blinks when the house humidity is above the set point. The HRV is forced to high speed ventilation no matter what speed was picked. Normal operation, not a fault.
Applies to: 99-BC02, 99-BC03 wall controls
Common causes of Lifebreath code Dehumidistat light flashing
- Indoor humidity is above the dehumidistat set point
Lifebreath models that use code Dehumidistat light flashing
Other Lifebreath Hrv codes
All Lifebreath Hrv error codes →
Lifebreath code Dehumidistat light flashing: homeowner questions
What does Lifebreath code Dehumidistat light flashing mean?
Dehumidistat calling, unit on high speed. On the BC02 or BC03 wall control the dehumidistat light blinks when the house humidity is above the set point. The HRV is forced to high speed ventilation no matter what speed was picked. Normal operation, not a fault.
Is it safe to keep using my heating or cooling system with code Dehumidistat light flashing?
Usually yes. Code Dehumidistat light flashing is normally minor, but if it keeps coming back have it checked.
Can I reset Lifebreath code Dehumidistat light flashing myself?
You can try one reset (power off for 30 seconds, then on). If Lifebreath code Dehumidistat light flashing comes back, the cause is still there and a licensed technician should check it.
Who can fix Lifebreath code Dehumidistat light flashing near me?
Aurora Star Tech Inc. repairs Lifebreath heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Troubleshooting guides
- Bathroom timer does not bring HRV to high Lifebreath · Hrv
- Clear the service reminder Lifebreath · Hrv
- Condensation or ice on insulated duct to outside Lifebreath · Hrv
- Core cleaning do's and don'ts Lifebreath · Hrv
- Core sticks out about 1/8 in Lifebreath · Hrv
- Dehumidistat does not work Lifebreath · Hrv
- DXPL02 20/40/60 high speed button Lifebreath · Hrv
- DXPL02 reset button defaults Lifebreath · Hrv
- HRV or ducts frosting up Lifebreath · Hrv
- HRV vibrates a lot Lifebreath · Hrv
- Humidity too high, condensation on windows Lifebreath · Hrv
- Humidity too low Lifebreath · Hrv
- Lock or unlock the 99-DET01 timer Lifebreath · Hrv
- Poor airflow from HRV Lifebreath · Hrv
- Power reset re-enables the dehumidistat Lifebreath · Hrv
- Self-test on every power-up Lifebreath · Hrv
- Supply air feels cold Lifebreath · Hrv
- Water in the bottom of the HRV Lifebreath · Hrv
Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Ventilation Controls BC02 / BC03, p. 5-6. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.