ICP Error Code LED off: Amber status LED off – no power / blown 3 A fuse (Furnace)
ICP error code LED off on a furnace means: Amber status LED off - no power / blown 3 A fuse. It is also called ICP diagnostic code LED off.
Homeowner? What ICP code LED off means for you
Call a technician Your furnace is reporting: Amber status LED off - no power / blown 3 A fuse. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does ICP error code LED off mean?
The control shows nothing. Usually no 115 V or 24 V at the board, an open door switch, or the 3-amp 24 V fuse is blown.
Applies to: ICP F9MAE / G9MAE modulating variable-speed condensing gas furnaces (060, 080, 100, 120 kBtu/h)
Common causes of ICP code LED off
- Blower door switch open
- Breaker off / no 115 V at L1-L2
- Blown 3-amp automotive fuse (24 V short)
A technician checks these and 1 other possible causes on site before replacing any part.
ICP models that use code LED off
G9MAE0601714G9MAE0602120G9MAE0801714G9MAE0802120G9MAE1002122G9MAE1202422
Other ICP Furnace codes
ICP code LED off: homeowner questions
What does ICP code LED off mean?
Amber status LED off - no power / blown 3 A fuse. The control shows nothing. Usually no 115 V or 24 V at the board, an open door switch, or the 3-amp 24 V fuse is blown.
Is it safe to keep using my furnace with code LED off?
It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset ICP code LED off myself?
You can try one reset (power off for 30 seconds, then on). If ICP code LED off comes back, the cause is still there and a licensed technician should check it.
Who can fix ICP code LED off near me?
Aurora Star Tech Inc. repairs ICP furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean
Troubleshooting guides
- Blower cycles on and off All brands · Furnace
- Blower runs, not enough heat All brands · Furnace
- Blowing cold air All brands · Furnace
- Board shows "flame sensed with no call for heat" All brands · Furnace
- Can't pull oil (distance/lift) All brands · Furnace
- CO in flue / poor combustion numbers All brands · Furnace
- Cold air blast at start / blower never stops All brands · Furnace
- Combustion gas / odour in house, flu-like symptoms All brands · Furnace
Source: ICP (F/G)9MAE Service and Technical Support Manual 440 04 4700 00, Figure 16 Troubleshooting Chart, p.33. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.