Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Gree Error Code SE: Energy-saving mode active (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code SE on a heat pump means: Energy-saving mode active. It is also called Gree diagnostic code SE.

Low severityHeat PumpGree Sapphire · Gree Livo GEN4 · Gree Vireo GEN3

Homeowner? What Gree code SE means for you

Usually minor Your heat pump is reporting: Energy-saving mode active. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code SE mean?

SE is shown on the remote when the energy-saving function is started in cooling mode (press TEMP and CLOCK together). The unit shifts the set temperature automatically to a factory energy-saving value, keeps the fan on auto and will not accept manual temperature or fan changes. Sleep and SE cancel each other. Not a fault.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A); Livo GEN4 30-36k (4LIV..HP230V1A); Vireo GEN3 9-24k (3VIR..HP115/230V1A)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code SE

3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1A4LIV30HP230V1AH4LIV36HP230V1AHSAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH

Other Gree Heat Pump codes

CodeMeaning
PHDC bus voltage too high
PJInverter compressor failed to start
PLDC bus voltage too low
Power LEDMain board and drive board power LEDs on
PPInverter compressor AC current protection
PUDC bus capacitor charging fault
Temp display selectIndoor display shows set, room or outdoor temperature
Turbo iconTurbo mode active
U0Compressor preheat not finished
U1Compressor phase current sensing fault
U2Outdoor capacity code / jumper wrong
U3DC bus voltage drop

All Gree Heat Pump error codes →

Gree code SE: homeowner questions

What does Gree code SE mean?

Energy-saving mode active. SE is shown on the remote when the energy-saving function is started in cooling mode (press TEMP and CLOCK together). The unit shifts the set temperature automatically to a factory energy-saving value, keeps the fan on auto and will not…

Is it safe to keep using my heat pump with code SE?

Usually yes. Code SE is normally minor, but if it keeps coming back have it checked.

Can I reset Gree code SE myself?

You can try one reset (power off for 30 seconds, then on). If Gree code SE comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code SE near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 6.1 remote controller, combination buttons; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 6.1 remote controller, combination buttons; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 6.1 function introduction for combination buttons; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 6.1 function introduction for combination buttons. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service