Gree Error Code Heat lamp: Heat lamp lit (heating mode) (Heat Pump)
Gree error code Heat lamp on a heat pump means: Heat lamp lit (heating mode). It is also called Gree diagnostic code Heat lamp.
Homeowner? What Gree code Heat lamp means for you
Usually minor Your heat pump is reporting: Heat lamp lit (heating mode). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Gree error code Heat lamp mean?
The Heat lamp on the indoor unit lights when heating mode is selected. Some models do not have this lamp.
Applies to: Livo GEN4 30-36k (4LIV..HP230V1A)
Gree models that use code Heat lamp
4LIV30HP230V1AH4LIV36HP230V1AH
Other Gree Heat Pump codes
All Gree Heat Pump error codes →
Gree code Heat lamp: homeowner questions
What does Gree code Heat lamp mean?
Heat lamp lit (heating mode). The Heat lamp on the indoor unit lights when heating mode is selected. Some models do not have this lamp.
Is it safe to keep using my heat pump with code Heat lamp?
Usually yes. Code Heat lamp is normally minor, but if it keeps coming back have it checked.
Can I reset Gree code Heat lamp myself?
You can try one reset (power off for 30 seconds, then on). If Gree code Heat lamp comes back, the cause is still there and a licensed technician should check it.
Who can fix Gree code Heat lamp near me?
Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 6.1 remote controller, mode button. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.