Gree Error Code Heat lamp 10 s on / 0.5 s off: Defrosting (heating lamp pattern) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code Heat lamp 10 s on / 0.5 s off on a heat pump means: Defrosting (heating lamp pattern). It is also called Gree diagnostic code Heat lamp 10 s on / 0.5 s off.

Low severityHeat PumpGree Sapphire · Gree Vireo GEN3

Homeowner? What Gree code Heat lamp 10 s on / 0.5 s off means for you

Usually minor Your heat pump is reporting: Defrosting (heating lamp pattern). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code Heat lamp 10 s on / 0.5 s off mean?

During defrosting in heating mode, the heating lamp stays off for 0.5 s and then blinks for 10 s (the Sapphire manual) or is on for 10 s and off for 0.5 s (the Vireo compulsory-defrost text). The temperature display can show H1 at the same time. Normal operation: the compressor keeps running while the indoor fan stops.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A); Vireo GEN3 9-24k (3VIR..HP115/230V1A)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code Heat lamp 10 s on / 0.5 s off

3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1ASAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH

Other Gree Heat Pump codes

CodeMeaning
H8Fan drive module overheated
H9Inverter fan lost synchronism
HAFan drive memory chip fault
HCPFC protection
HEInverter fan phase loss
Heat lampHeat lamp lit (heating mode)
HFFan drive charging circuit fault
HHFan drive DC bus voltage too high
HJInverter fan failed to start
HLFan drive DC bus voltage too low
HPInverter fan AC current protection
HUFan drive AC input voltage fault

All Gree Heat Pump error codes →

Gree code Heat lamp 10 s on / 0.5 s off: homeowner questions

What does Gree code Heat lamp 10 s on / 0.5 s off mean?

Defrosting (heating lamp pattern). During defrosting in heating mode, the heating lamp stays off for 0.5 s and then blinks for 10 s (the Sapphire manual) or is on for 10 s and off for 0.5 s (the Vireo compulsory-defrost text). The temperature display can show H1 at the…

Is it safe to keep using my heat pump with code Heat lamp 10 s on / 0.5 s off?

Usually yes. Code Heat lamp 10 s on / 0.5 s off is normally minor, but if it keeps coming back have it checked.

Can I reset Gree code Heat lamp 10 s on / 0.5 s off myself?

You can try one reset (power off for 30 seconds, then on). If Gree code Heat lamp 10 s on / 0.5 s off comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code Heat lamp 10 s on / 0.5 s off near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 6.2 (10) Display, double-8 display; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 6.2 (10) Display, double-8 display; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 6.2 (9) compulsory defrosting function. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977