Goodman Error Code 04: Locked rotor (Heat Pump)

Updated · by Aurora Star Tech Inc.

Goodman error code 04 on a heat pump means: Locked rotor. It is also called Goodman diagnostic code 04.

Critical severityHeat PumpGoodman/Amana ComfortNet ASZC/GSZC/DSZC

Homeowner? What Goodman code 04 means for you

Stop and call Your heat pump is reporting: Locked rotor. This code is a safety shutdown. Turn the heat pump off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code 04 mean?

The compressor protector tripped 4 times in a row with an average run time under 15 seconds. Compressor and outdoor fan are off.

Applies to: Communicating 2-stage condensers and heat pumps with the PCBHR104 or PCBHR105 outdoor control (7-segment display): ASXC16/18, GSXC16/18, DSXC16/18, ASZC16/18, GSZC16/18, DSZC16/18

Common causes of Goodman code 04

  • Seized compressor bearings
  • Failed run capacitor or bad capacitor wiring
  • Low line voltage
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code 04

Show all 24 models

ASZC160241ASZC160361ASZC160421ASZC160481ASZC160601ASZC180241ASZC180361ASZC180481ASZC180601DSZC160241DSZC160361DSZC160481DSZC160601DSZC180361DSZC180481DSZC180601GSZC160241GSZC160361GSZC160481GSZC160601GSZC180241GSZC180361GSZC180481GSZC180601

Other Goodman Heat Pump codes

CodeMeaning
01Low side fault or low pressure switch trip
02High side fault or high pressure switch trip
03Short cycling
05Open circuit - compressor off over 4 hours
06Open start circuit
07Open run circuit
08No line voltage
09Low 24 V control voltage
A2Outdoor air temperature sensor fault
A3Outdoor coil temperature sensor fault
b0Indoor blower not running when it should be
b9Indoor airflow lower than requested

All Goodman Heat Pump error codes →

Goodman code 04: homeowner questions

What does Goodman code 04 mean?

Locked rotor. The compressor protector tripped 4 times in a row with an average run time under 15 seconds. Compressor and outdoor fan are off.

Is it safe to keep using my heat pump with code 04?

No. Code 04 is a safety shutdown, so keep the heat pump off until a licensed technician has checked it.

Can I reset Goodman code 04 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Goodman code 04 near me?

Aurora Star Tech Inc. repairs Goodman heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Goodman ComfortNet ASXC/GSXC/DSXC, ASZC/GSZC/DSZC, AVPTC/MBVC service manual, Unitary Diagnostic Codes PCBHR104 p.71-77 and PCBHR105 p.78-84. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977