Goodman Error Code CoreSense 2: Pressure trip – yellow 2 flashes (red 2 = lockout) (AC)
Goodman error code CoreSense 2 on a air conditioner means: Pressure trip - yellow 2 flashes (red 2 = lockout). It is also called Goodman diagnostic code CoreSense 2.
Homeowner? What Goodman code CoreSense 2 means for you
Call a technician Your air conditioner is reporting: Pressure trip - yellow 2 flashes (red 2 = lockout). The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
- If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Goodman error code CoreSense 2 mean?
Compressor ran 12 s to 15 min, then tripped for longer than 7 min (discharge pressure too high or overload). Red 2 flashes with yellow off = locked out after 4 trips in a row or 10 total.
Applies to: Copeland CoreSense 3-wire module: Amana/Deluxe R-410A ASX, ASZ, DSX, DSZ units and Amana R-32 ALXS / ALZS units
Common causes of Goodman code CoreSense 2
- Outdoor fan not running (capacitor, wiring, motor)
- High head pressure: high pressure switch, overcharge, non-condensables
- Dirty, blocked or damaged outdoor coil
Goodman models that use code CoreSense 2
Show all 150 models
ALXS3BN**10AAALXS4BA**10AAALXS4NA**10AAALXS5BA**10AAANX130181ANX130241ANX130301ANX130361ANX130421ANX130481ANX130601ANX130611ANX140181ANX140191ANX140241ANX140251ANX140301ANX140361ANX140371ANX140421ANX140431ANX140481ANX140601ASX180**1ABASX130181ASX130241ASX130301ASX130361ASX130421ASX130481ASX130601ASX130611ASX140181ASX140191ASX140241ASX140251ASX140301ASX140311ASX140361ASX140371ASX140421ASX140431ASX140481ASX140601ASX160181ASX160241ASX160301ASX160311ASX160361ASX160371ASX160421ASX160481ASX160601ASX160611ASXH5***10DSX160241DSX160361GLXS3BN**10AAGLXS4BA**10AAGLXS4MA**10AAGLXS5BA**10AAGSX16A181GSX16A241GSX16A301GSX16A361GSX16A421GSX16A481GSX16A601GSX16S181GSX16S241GSX16S301GSX16S361GSX16S421GSX16S481GSX110903GSX110904GSX111203GSX111204GSX130181GSX130241GSX130301GSX130361GSX130363GSX130371GSX130421GSX130481GSX130483GSX130484GSX130601GSX130603GSX130604GSX130611GSX140181GSX140191GSX140241GSX140251GSX140301GSX140311GSX140361GSX140371GSX140421GSX140431GSX140481GSX140601GSX160181GSX160241GSX160301GSX160311GSX160361GSX160371GSX160421GSX160481GSX160601GSX160611GSXH5***10SSX140181SSX140241SSX140301SSX140361SSX140421SSX140481SSX140601SSX160241SSX160301SSX160361SSX160421SSX160481SSX160591SSX160601VSX130181VSX130241VSX130301VSX130361VSX130371VSX130421VSX130481VSX130601VSX130611VSX140181VSX140191VSX140241VSX140251VSX140301VSX140311VSX140361VSX140371VSX140421VSX140431VSX140481VSX140601
Other Goodman AC codes
All Goodman Air Conditioner error codes →
Goodman code CoreSense 2: homeowner questions
What does Goodman code CoreSense 2 mean?
Pressure trip - yellow 2 flashes (red 2 = lockout). Compressor ran 12 s to 15 min, then tripped for longer than 7 min (discharge pressure too high or overload). Red 2 flashes with yellow off = locked out after 4 trips in a row or 10 total.
Is it safe to keep using my air conditioner with code CoreSense 2?
It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Goodman code CoreSense 2 myself?
You can try one reset (power off for 30 seconds, then on). If Goodman code CoreSense 2 comes back, the cause is still there and a licensed technician should check it.
Who can fix Goodman code CoreSense 2 near me?
Aurora Star Tech Inc. repairs Goodman air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check
Troubleshooting guides
- Not cooling All brands · Air Conditioner
- No cooling - R-32 GLXS/ALXS condenser Goodman · Air Conditioner
Source: Goodman RS6200301 R-32 GLXS/ALXS/GLZS/ALZS service (07-2024), CoreSense Diagnostics Table p.21-22 and Quick Reference Table p.23; Goodman RS6200006r103 R-410A ASX/GSX/DSX/ASZ/GSZ/DSZ service (text export) (Goodman_R_410A_ASX_GSX_DSX_A_C_and_ASZ_GSZ_DSZ_HP_covers_GSX_GSZ_lines_GSXH5_GSZH5_service.txt section Diagnostics Table: Coresense Module / Table 1 Quick Reference). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.