Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman Error Code 05: Open circuit – compressor off over 4 hours (AC)

Updated · by Aurora Star Tech Inc.

Goodman error code 05 on a air conditioner means: Open circuit - compressor off over 4 hours. It is also called Goodman diagnostic code 05.

High severityAir ConditionerAlso Heat PumpGoodman/Amana ComfortNet ASXC/GSXC/DSXC

Homeowner? What Goodman code 05 means for you

Call a technician Your air conditioner is reporting: Open circuit - compressor off over 4 hours. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Goodman error code 05 mean?

Compressor and outdoor fan have been off for more than 4 hours with both pressure switches closed - the control sees no compressor current.

Applies to: Communicating 2-stage condensers and heat pumps with the PCBHR104 or PCBHR105 outdoor control (7-segment display): ASXC16/18, GSXC16/18, DSXC16/18, ASZC16/18, GSZC16/18, DSZC16/18

Common causes of Goodman code 05

  • Power disconnected (breaker, fuse, disconnect)
  • Compressor internal protector failed open
  • Compressor not wired correctly to the control
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Goodman models that use code 05

Show all 23 models

ASXC160241ASXC160361ASXC160481ASXC160601ASXC180241ASXC180361ASXC180481ASXC180601DSXC160241DSXC160361DSXC160481DSXC160601DSXC180361DSXC180481DSXC180601GSXC160241GSXC160361GSXC160481GSXC160601GSXC180241GSXC180361GSXC180481GSXC180601

Other Goodman AC codes

CodeMeaning
01Low side fault or low pressure switch trip
02High side fault or high pressure switch trip
03Short cycling
04Locked rotor
06Open start circuit
07Open run circuit
08No line voltage
09Low 24 V control voltage
b0Indoor blower not running when it should be
b9Indoor airflow lower than requested
Comfort Alert 1Yellow ALERT 1 flash - long run time
Comfort Alert 2Yellow ALERT 2 flashes - system pressure trip

All Goodman Air Conditioner error codes →

Goodman code 05: homeowner questions

What does Goodman code 05 mean?

Open circuit - compressor off over 4 hours. Compressor and outdoor fan have been off for more than 4 hours with both pressure switches closed - the control sees no compressor current.

Is it safe to keep using my air conditioner with code 05?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Goodman code 05 myself?

You can try one reset (power off for 30 seconds, then on). If Goodman code 05 comes back, the cause is still there and a licensed technician should check it.

Who can fix Goodman code 05 near me?

Aurora Star Tech Inc. repairs Goodman air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Goodman ComfortNet ASXC/GSXC/DSXC, ASZC/GSZC/DSZC, AVPTC/MBVC service manual, Unitary Diagnostic Codes PCBHR104 p.71-77 and PCBHR105 p.78-84. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977