Glow Brand Error Code tESt: System test active (Boiler)

Updated · by Aurora Star Tech Inc.

Glow Brand error code tESt on a boiler means: System test active. It is also called Glow Brand diagnostic code tESt.

Low severityBoilerGlow B85/B120/B160

Homeowner? What Glow Brand code tESt means for you

Usually minor Your boiler is reporting: System test active. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Glow Brand error code tESt mean?

The installer system test is running; the small digits alternate between tESt and the active test (FAN, Lo, Ign, Hi, REg, Stb, LCO1). The boiler is locked in CH mode and needs a heat load.

Applies to: B85, B120, B160 (NG and LP)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Glow Brand models that use code tESt

B85B120B160

Other Glow Brand Boiler codes

CodeMeaning
Loc 20Flame still present 10 s after gas valve closed
Loc 21Flame detected before ignition
Loc 22Three flame failures in one demand
Loc 23Error code memory corrupted
Loc 33Low water cut-off circuit open
Loc 38Blocked flue switch tripped more than 3 times in 24 h

All Glow Brand Boiler error codes →

Glow Brand code tESt: homeowner questions

What does Glow Brand code tESt mean?

System test active. The installer system test is running; the small digits alternate between tESt and the active test (FAN, Lo, Ign, Hi, REg, Stb, LCO1). The boiler is locked in CH mode and needs a heat load.

Is it safe to keep using my boiler with code tESt?

Usually yes. Code tESt is normally minor, but if it keeps coming back have it checked.

Can I reset Glow Brand code tESt myself?

You can try one reset (power off for 30 seconds, then on). If Glow Brand code tESt comes back, the cause is still there and a licensed technician should check it.

Who can fix Glow Brand code tESt near me?

Aurora Star Tech Inc. repairs Glow Brand boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Glow Brand B85/B120/B160 Installation & Operation Manual V20231025, 11.10 p.60. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.