Mitsubishi Error Code PLEASE WAIT: Remote controller start-up message (Heat Pump)

Updated · by Aurora Star Tech Inc.

Mitsubishi error code PLEASE WAIT on a heat pump means: Remote controller start-up message. It is also called Mitsubishi diagnostic code PLEASE WAIT.

Low severityHeat PumpMr. Slim PEAD-RP JA(L) ducted indoor unit

Homeowner? What Mitsubishi code PLEASE WAIT means for you

Usually minor Your heat pump is reporting: Remote controller start-up message. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Mitsubishi error code PLEASE WAIT mean?

The wired remote shows PLEASE WAIT after power is applied to the indoor unit or after recovery from a power failure. The part-names page says it stays about 3 minutes; the troubleshooting page says remote operation is blocked for about 2 minutes while the system starts. During this time the outdoor board shows LED1 and LED2 lit, then LED2 goes out and LED1 stays lit. All of this is correct operation. If PLEASE WAIT is followed by an error code after about 2 minutes, that is a real fault.

Applies to: Mr. Slim PEAD-RP JA(L) ducted indoor units with PAR-21MAA wired remote

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Mitsubishi models that use code PLEASE WAIT

PEAD-RP35JAPEAD-RP35JALPEAD-RP50JAPEAD-RP50JALPEAD-RP60JAPEAD-RP60JALPEAD-RP71JAPEAD-RP71JALPEAD-RP100JAPEAD-RP100JALPEAD-RP125JAPEAD-RP125JALPEAD-RP140JAPEAD-RP140JAL

Other Mitsubishi Heat Pump codes

CodeMeaning
P4Drain float switch disconnected
P5Drain overflow - float switch wet with pump running
P6Coil freeze or overheat protection
P8Pipe temperature out of range (coil not cooling or heating)
P9Coil sensor TH5 open or shorted
PAWater leak detected
Power On indicatorPower on indicator
Room temperature blinkingRoom temperature out of display range
Self-check (wired remote)Remote controller self-check mode
Self-check beeps (wireless remote)Wireless remote self-check feedback
Sensor indicationRemote's own temperature sensor in use
TEST RUN (wireless remote)Wireless remote test run

All Mitsubishi Heat Pump error codes →

Mitsubishi code PLEASE WAIT: homeowner questions

What does Mitsubishi code PLEASE WAIT mean?

Remote controller start-up message. The wired remote shows PLEASE WAIT after power is applied to the indoor unit or after recovery from a power failure. The part-names page says it stays about 3 minutes; the troubleshooting page says remote operation is blocked for about 2…

Is it safe to keep using my heat pump with code PLEASE WAIT?

Usually yes. Code PLEASE WAIT is normally minor, but if it keeps coming back have it checked.

Can I reset Mitsubishi code PLEASE WAIT myself?

You can try one reset (power off for 30 seconds, then on). If Mitsubishi code PLEASE WAIT comes back, the cause is still there and a licensed technician should check it.

Who can fix Mitsubishi code PLEASE WAIT near me?

Aurora Star Tech Inc. repairs Mitsubishi heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Mitsubishi PEAD-RP35JA(L) Service Manual, Part Names and Functions p.4; Troubleshooting 10-2, pp.28-30. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.