Mitsubishi Error Code P5: Drain overflow – float switch wet with pump running (Heat Pump)
Mitsubishi error code P5 on a heat pump means: Drain overflow - float switch wet with pump running. It is also called Mitsubishi diagnostic code P5.
Homeowner? What Mitsubishi code P5 means for you
Call a technician Your heat pump is reporting: Drain overflow - float switch wet with pump running. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Mitsubishi error code P5 mean?
The float switch has been under water for 90 seconds with the drain pump on. The compressor and indoor fan stop; if it happens again the unit locks out with P5.
Applies to: PEAD-RP35/50/60/71/100/125/140JA and JA(L) ducted indoor units (220-240 V models)
Common causes of Mitsubishi code P5
- Drain pump not working
- Drain pump or condensate line clogged
- Float switch stuck in the up (wet) position
A technician checks these and 1 other possible causes on site before replacing any part.
Mitsubishi models that use code P5
PEAD-RP35JAPEAD-RP35JALPEAD-RP50JAPEAD-RP50JALPEAD-RP60JAPEAD-RP60JALPEAD-RP71JAPEAD-RP71JALPEAD-RP100JAPEAD-RP100JALPEAD-RP125JAPEAD-RP125JALPEAD-RP140JAPEAD-RP140JAL
Other Mitsubishi Heat Pump codes
All Mitsubishi Heat Pump error codes →
Mitsubishi code P5: homeowner questions
What does Mitsubishi code P5 mean?
Drain overflow - float switch wet with pump running. The float switch has been under water for 90 seconds with the drain pump on. The compressor and indoor fan stop; if it happens again the unit locks out with P5.
Is it safe to keep using my heat pump with code P5?
It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Mitsubishi code P5 myself?
You can try one reset (power off for 30 seconds, then on). If Mitsubishi code P5 comes back, the cause is still there and a licensed technician should check it.
Who can fix Mitsubishi code P5 near me?
Aurora Star Tech Inc. repairs Mitsubishi heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Mitsubishi Electric PEAD-RP35-140JA(L) Service Manual, 10-3 Self-diagnosis action table, p.31. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.