Bosch Error Code Force button: Force button – forced cooling/heating (charge mode) (Heat Pump)
Bosch error code Force button on a heat pump means: Force button - forced cooling/heating (charge mode). It is also called Bosch diagnostic code Force button.
Homeowner? What Bosch code Force button means for you
Usually minor Your heat pump is reporting: Force button - forced cooling/heating (charge mode). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Bosch error code Force button mean?
A short press of the FORCE button (SW1) while the unit is running in cooling puts it in forced operation at full capacity for checking charge. The unit only runs in this mode when the user starts it. The manual says a symbol appears on the display; the symbol could not be read from the text export. On IDS 2.0 the display then shows a bar symbol followed by the compressor frequency.
Applies to: BOVA IDS 2.0, IDS Premium Connected and IDS Light heat pumps
Bosch models that use code Force button
BOVA-36HDN1-M20GBOVA-60HDN1-M20GBOVA15-24BOVA15-36BOVA15-60BOVA36-20BOVA60-20
Other Bosch Heat Pump codes
All Bosch Heat Pump error codes →
Bosch code Force button: homeowner questions
What does Bosch code Force button mean?
Force button - forced cooling/heating (charge mode). A short press of the FORCE button (SW1) while the unit is running in cooling puts it in forced operation at full capacity for checking charge. The unit only runs in this mode when the user starts it. The manual says a symbol appears on…
Is it safe to keep using my heat pump with code Force button?
Usually yes. Code Force button is normally minor, but if it keeps coming back have it checked.
Can I reset Bosch code Force button myself?
You can try one reset (power off for 30 seconds, then on). If Bosch code Force button comes back, the cause is still there and a licensed technician should check it.
Who can fix Bosch code Force button near me?
Aurora Star Tech Inc. repairs Bosch heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Force cooling for charging with the FORCE button Bosch · Heat Pump
- Pair the gateway by Bluetooth (Connect button) Bosch · Heat Pump
- Read system values with the CHECK button (point check) Bosch · Heat Pump
- Restart the gateway (Reset button) Bosch · Heat Pump
- Run the gateway diagnostic (Factory + Connect buttons) Bosch · Heat Pump
- Start a manual defrost test (hold FORCE 6 s) Bosch · Heat Pump
Source: Bosch IDS Premium Connected BTC 762003301 D (02.2025), 17.2 Subcooling Charging p.43-44; IDS 2.0 service Rev3 (07.2021), 10.2.2 Force Mode Operation p.32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.