Gree Heat Pump: Weak cooling or heating – Gree ductless

Updated · by Aurora Star Tech Inc.

Weak cooling or heating - Gree ductless on a Gree heat pump: Unit runs but room temperature is not reached.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)

Common causes of weak cooling or heating - gree ductless

  • Setpoint or fan speed too low
  • Dirty filter
  • Poor indoor/outdoor unit location
  • Refrigerant leak
  • 4-way valve fault (cold air in heating)
  • Capillary/EEV restriction
  • Service valve not fully open

How to fix weak cooling or heating - gree ductless: step by step

  1. Check setpoint and set fan to high or medium.
  2. Clean the filter.
  3. Check installation clearances and shading of the outdoor unit.
  4. Compare supply air temperature and pressures with normal; low readings point to a leak or restriction.
  5. Open both service valves fully.
  6. Cold air in heating with good charge: replace the 4-way valve.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Gree Heat Pump codes

Models

Gree Vireo GEN3

3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1A

Gree Livo GEN4

4LIV30HP230V1AH4LIV36HP230V1AH

Gree GMV6 Mini VRF

GMV-V36WL/C-T(U)GMV-V48WL/C-T(U)GMV-V60WL/C-T(U)

Gree Multi21+

MULTI18HP230V1COMULTI24HP230V1CO

Gree Sapphire

SAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.3 Troubleshooting for Normal Malfunction; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.3 Maintenance Method for Normal Malfunction. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.