York Error Code 5 red flashes: Rollout switch open / limit circuit open over 15 min (Furnace)

Updated · by Aurora Star Tech Inc.

York error code 5 red flashes on a furnace means: Rollout switch open / limit circuit open over 15 min. It is also called York diagnostic code 5 red flashes.

Critical severityFurnaceYork UTEC IFC furnaces · York White-Rodgers IFC furnaces · York TM9V

Homeowner? What York code 5 red flashes means for you

Stop and call Your furnace is reporting: Rollout switch open / limit circuit open over 15 min. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does York error code 5 red flashes mean?

The limit circuit has been open long enough that the board assumes a manual-reset rollout switch has tripped (White-Rodgers boards also show this for an open fuse). Hard lockout - power must be cycled after repair.

Applies to: York/JCI residential gas furnaces: York UTEC IFC furnaces, York White-Rodgers IFC furnaces, York TM9V

Common causes of York code 5 red flashes

  • Blocked heat exchanger or vent causing flame rollout
  • Inducer failure
  • Cracked primary heat exchanger

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

York models that use code 5 red flashes

TM9V040A10TM9V060B12TM9V080B12TM9V080C16TM9V100C16TM9V100C20TM9V120D20

Other York Furnace codes

CodeMeaning
3 amber flashesW2 call without W1
3 double red flashesSecond-stage pressure switch not closing
3 green flashesFault memory cleared
3 red flashesPressure switch open when it should be closed
4 amber flashesCooling call (Y) without fan call (G)
4 red flashesMain limit switch open
6 red flashesPressure switch cycling lockout
7 red flashesIgnition failure lockout (retries)
8 red flashesFlame lost repeatedly (recycles)
9 red flashesPolarity reversed or bad ground
10 red flashesGas valve powered with no heat call
11 red flashesLimit open 5-15 minutes - blower failure

All York Furnace error codes →

York code 5 red flashes: homeowner questions

What does York code 5 red flashes mean?

Rollout switch open / limit circuit open over 15 min. The limit circuit has been open long enough that the board assumes a manual-reset rollout switch has tripped (White-Rodgers boards also show this for an open fuse). Hard lockout - power must be cycled after repair.

Is it safe to keep using my furnace with code 5 red flashes?

No. Code 5 red flashes is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset York code 5 red flashes myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix York code 5 red flashes near me?

Aurora Star Tech Inc. repairs York furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: York All JCI single-two-stage furnaces with UTEC IFC board codes ST-045-09.pdf - section Fault Code LED Flashes; York JCI single-two-stage furnaces with White-Rodgers-Emerson IFC (older installed base) codes ST-028-07.pdf - section Fault Code Sheets; York TM9V - -M9V 96% two-stage variable speed installation 1083294-UIM-A-0114.pdf - section Furnace Control Diagnostics. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.