Updated · by Aurora Star Tech Inc.

York error code 2 red flashes on a furnace means: Pressure switch closed when it should be open. It is also called York diagnostic code 2 red flashes.

Medium severityFurnaceYork UTEC IFC furnaces · York White-Rodgers IFC furnaces · York TM9V

Homeowner? What York code 2 red flashes means for you

Check, then call Your furnace is reporting: Pressure switch closed when it should be open. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does York error code 2 red flashes mean?

At the start of the heat call the pressure switch contacts are already closed before the inducer runs, so the board will not continue ignition.

Applies to: York/JCI residential gas furnaces: York UTEC IFC furnaces, York White-Rodgers IFC furnaces, York TM9V

Common causes of York code 2 red flashes

  • Pressure switch contacts stuck closed
  • Miswired pressure switch
  • Jumpered switch
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

York models that use code 2 red flashes

TM9V040A10TM9V060B12TM9V080B12TM9V080C16TM9V100C16TM9V100C20TM9V120D20

Other York Furnace codes

CodeMeaning
1 red flashFlame detected with gas valve off
3 amber flashesW2 call without W1
3 double red flashesSecond-stage pressure switch not closing
3 red flashesPressure switch open when it should be closed
4 amber flashesCooling call (Y) without fan call (G)
4 red flashesMain limit switch open
5 red flashesRollout switch open / limit circuit open over 15 min
6 red flashesPressure switch cycling lockout
7 red flashesIgnition failure lockout (retries)
8 red flashesFlame lost repeatedly (recycles)
9 red flashesPolarity reversed or bad ground
10 red flashesGas valve powered with no heat call

All York Furnace error codes →

York code 2 red flashes: homeowner questions

What does York code 2 red flashes mean?

Pressure switch closed when it should be open. At the start of the heat call the pressure switch contacts are already closed before the inducer runs, so the board will not continue ignition.

Is it safe to keep using my furnace with code 2 red flashes?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset York code 2 red flashes myself?

You can try one reset (power off for 30 seconds, then on). If York code 2 red flashes comes back, the cause is still there and a licensed technician should check it.

Who can fix York code 2 red flashes near me?

Aurora Star Tech Inc. repairs York furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: York All JCI single-two-stage furnaces with UTEC IFC board codes ST-045-09.pdf - section Fault Code LED Flashes; York JCI single-two-stage furnaces with White-Rodgers-Emerson IFC (older installed base) codes ST-028-07.pdf - section Fault Code Sheets; York TM9V - -M9V 96% two-stage variable speed installation 1083294-UIM-A-0114.pdf - section Furnace Control Diagnostics. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.