KeepRite Error Code 47: No 230 V at the unit (Heat Pump)
KeepRite error code 47 on a heat pump means: No 230 V at the unit. It is also called KeepRite diagnostic code 47.
Homeowner? What KeepRite code 47 means for you
Call a technician Your heat pump is reporting: No 230 V at the unit. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does KeepRite error code 47 mean?
Indoor unit is powered and there is a call, but no line voltage is reaching the contactor.
Applies to: KeepRite *CA7/*CA9 AC and *CH6/*CH9 HP two-stage communicating
Common causes of KeepRite code 47
- Disconnect open
- Line voltage wiring not connected
KeepRite models that use code 47
*CH624*CH636*CH648*CH660*CH924*CH936*CH948*CH960
Other KeepRite Heat Pump codes
All KeepRite Heat Pump error codes →
KeepRite code 47: homeowner questions
What does KeepRite code 47 mean?
No 230 V at the unit. Indoor unit is powered and there is a call, but no line voltage is reaching the contactor.
Is it safe to keep using my heat pump with code 47?
It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset KeepRite code 47 myself?
You can try one reset (power off for 30 seconds, then on). If KeepRite code 47 comes back, the cause is still there and a licensed technician should check it.
Who can fix KeepRite code 47 near me?
Aurora Star Tech Inc. repairs KeepRite heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Forcing a defrost to test the board - KeepRite N4H4/R4H4/WCH4/NXH5 KeepRite · Heat Pump
- Outdoor unit will not run or will not defrost - KeepRite heat pump defrost board (FAST 1173636/1177927/1190281) KeepRite · Heat Pump
Source: KeepRite_ICP_KeepRite_Tempstar_Heil_split_A_C_HP_R_410A_R_22_service_421_08_5400_04.txt - section Table 17 Troubleshooting (two-stage). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.