Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Fujitsu Error Code 29: Connection unit number error (wired remote system) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Fujitsu error code 29 on a heat pump means: Connection unit number error (wired remote system). It is also called Fujitsu diagnostic code 29.

Low severityHeat PumpFujitsu ductless split/multi/VRF (general code list) · Fujitsu slim duct ARU 7-18 (LL type)

Homeowner? What Fujitsu code 29 means for you

Usually minor Your heat pump is reporting: Connection unit number error (wired remote system). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Fujitsu error code 29 mean?

Too many units on one wired remote controller group. Indoor lamps: OPERATION (green) flashes 2x, TIMER (orange) flashes 9x, ECONOMY (green) flashes fast nonstop; wired remote shows 29.

Applies to: Fujitsu ductless heat pumps: Fujitsu ductless split/multi/VRF (general code list), Fujitsu slim duct ARU 7-18 (LL type)

Common causes of Fujitsu code 29

  • More than the allowed units on one remote
  • Remote address settings wrong
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Fujitsu Heat Pump codes

CodeMeaning
21Address / refrigerant circuit setting error
22Indoor unit capacity error
23Combination error
24Connection unit number error
26Indoor unit address setting error
27Primary / secondary unit setup error
31Power supply interruption error
32Indoor main PCB error (EEPROM / model info)
33Indoor fan motor power consumption error
35MANUAL AUTO button error
39Indoor fan motor power supply error
41Room (intake air) temperature sensor error

All Fujitsu Heat Pump error codes →

Fujitsu code 29: homeowner questions

What does Fujitsu code 29 mean?

Connection unit number error (wired remote system). Too many units on one wired remote controller group. Indoor lamps: OPERATION (green) flashes 2x, TIMER (orange) flashes 9x, ECONOMY (green) flashes fast nonstop; wired remote shows 29.

Is it safe to keep using my heat pump with code 29?

Usually yes. Code 29 is normally minor, but if it keeps coming back have it checked.

Can I reset Fujitsu code 29 myself?

You can try one reset (power off for 30 seconds, then on). If Fujitsu code 29 comes back, the cause is still there and a licensed technician should check it.

Who can fix Fujitsu code 29 near me?

Aurora Star Tech Inc. repairs Fujitsu heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Fujitsu All Fujitsu split - multi - VRF (generic code list) codes.pdf - section error code table (indoor LED flashes); Fujitsu Slim duct AR07-09-12-14-18 (ARU-ARYG LL-type equivalent) installation P-N 9381858064.pdf - section 14 Error codes. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service