Bosch Error Code FA: Flame detected after gas shut off (Boiler)
Bosch error code FA on a boiler means: Flame detected after gas shut off. It is also called Bosch diagnostic code FA.
Homeowner? What Bosch code FA means for you
Stop and call Your boiler is reporting: Flame detected after gas shut off. This code is a safety shutdown. Turn the boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Bosch error code FA mean?
A flame signal remains after the gas valve closes.
Applies to: Bosch Greenstar ZBR 21/28/35/42-3A boilers and ZWB 28/35/42-3A combi boilers
Common causes of Bosch code FA
- Gas valve leaking through
- Dirty condensate trap
- Electrode or lead fault
A technician checks these and 1 other possible causes on site before replacing any part.
Bosch models that use code FA
ZBR21-3AZBR28-3AZBR35-3AZBR42-3A
Other Bosch Boiler codes
All Bosch Boiler error codes →
Bosch code FA: homeowner questions
What does Bosch code FA mean?
Flame detected after gas shut off. A flame signal remains after the gas valve closes.
Is it safe to keep using my boiler with code FA?
No. Code FA is a safety shutdown, so keep the boiler off until a licensed technician has checked it.
Can I reset Bosch code FA myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Bosch code FA near me?
Aurora Star Tech Inc. repairs Bosch boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Boiler Not Heating: What to Check
Troubleshooting guides
- Condensing/corrosion of conventional boiler All brands · Boiler
- No heat or some zones cold All brands · Boiler
- Noise All brands · Boiler
- Poor heat / circulation All brands · Boiler
- Relief valve weeps every cycle / pressure climbs All brands · Boiler
- Short cycling / wasted fuel All brands · Boiler
- Symptoms of air in system All brands · Boiler
- Uneven heating All brands · Boiler
Source: Bosch Greenstar ZBR/ZWB 21-42-3A service manual 6721853955 (2025-11), Table 38 Faults shown on the display, p.74-75; Greenstar combi 100 p/151 p service manual 6721853953 (2025-11), Table 33. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.