Bosch Error Code E2: Supply temperature sensor fault (Boiler)

Updated · by Aurora Star Tech Inc.

Bosch error code E2 on a boiler means: Supply temperature sensor fault. It is also called Bosch diagnostic code E2.

High severityBoilerBosch Greenstar

Homeowner? What Bosch code E2 means for you

Call a technician Your boiler is reporting: Supply temperature sensor fault. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Bosch error code E2 mean?

The boiler flow temperature sensor reads as faulty.

Applies to: Bosch Greenstar ZBR 21/28/35/42-3A boilers and ZWB 28/35/42-3A combi boilers

Common causes of Bosch code E2

  • Open or shorted sensor or lead
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Bosch models that use code E2

ZBR21-3AZBR28-3AZBR35-3AZBR42-3A

Other Bosch Boiler codes

CodeMeaning
b2/b3/b4/b5/b6Internal data error
b7Burner control fault
C6Fan not running
CCOutdoor temperature sensor not recognised
d3High limit / temperature limiter circuit open
d5External supply temperature sensor fault (low-loss header)
E3Additional supply temperature sensor fault
E9Safety high limit or flue gas limiter tripped
EANo flame detected
F0Internal fault
F1Internal data error
F7Flame detected with burner off

All Bosch Boiler error codes →

Bosch code E2: homeowner questions

What does Bosch code E2 mean?

Supply temperature sensor fault. The boiler flow temperature sensor reads as faulty.

Is it safe to keep using my boiler with code E2?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Bosch code E2 myself?

You can try one reset (power off for 30 seconds, then on). If Bosch code E2 comes back, the cause is still there and a licensed technician should check it.

Who can fix Bosch code E2 near me?

Aurora Star Tech Inc. repairs Bosch boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Bosch Greenstar ZBR/ZWB 21-42-3A service manual 6721853955 (2025-11), Table 38 Faults shown on the display, p.74-75; Greenstar combi 100 p/151 p service manual 6721853953 (2025-11), Table 33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.