Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code Green & Red simultaneous FAST flash: Ambient (outdoor air) sensor problem (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code Green & Red simultaneous FAST flash on a heat pump means: Ambient (outdoor air) sensor problem. It is also called Lennox diagnostic code Green & Red simultaneous FAST flash.

Medium severityHeat PumpLennox EL16KP1 · Lennox ML14KP1

Homeowner? What Lennox code Green & Red simultaneous FAST flash means for you

Check, then call Your heat pump is reporting: Ambient (outdoor air) sensor problem. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code Green & Red simultaneous FAST flash mean?

The outdoor ambient sensor reads open, shorted or out of range. The control falls back to time/temperature defrost; the system still heats and cools.

Applies to: Lennox EL16KP1 (Elite) and ML14KP1 (Merit) R-454B heat pumps, sizes -018 to -060, demand defrost control A108 (CMC1)

Common causes of Lennox code Green & Red simultaneous FAST flash

  • Ambient sensor open or shorted
  • Ambient sensor unplugged or loose at P4 (AMB-BLACK)
  • Damaged sensor wiring
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code Green & Red simultaneous FAST flash

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
E444Reversing valve relay or solenoid fault
E446Low suction pressure fault
E600Load shed event
E601Low ambient operational lockout
Green & Red alternating FAST flashCoil (defrost) sensor problem
Green & Red alternating SLOW flash5-minute anti-short-cycle delay
Green & Red simultaneous SLOW flashNormal operation or standby
Green FAST flash / Red OFFDischarge sensor lockout
Green FAST flash / Red ONDischarge line temperature lockout
Green OFF / Red FAST flashDischarge sensor fault
Green OFF / Red OFFNo power to the demand defrost control
Green OFF / Red ONLow pressure lockout

All Lennox Heat Pump error codes →

Lennox code Green & Red simultaneous FAST flash: homeowner questions

What does Lennox code Green & Red simultaneous FAST flash mean?

Ambient (outdoor air) sensor problem. The outdoor ambient sensor reads open, shorted or out of range. The control falls back to time/temperature defrost; the system still heats and cools.

Is it safe to keep using my heat pump with code Green & Red simultaneous FAST flash?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code Green & Red simultaneous FAST flash myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code Green & Red simultaneous FAST flash comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code Green & Red simultaneous FAST flash near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox EL16KP1 Unit Information 100195 / ML14KP1 Unit Information 100108, Table 4 Demand Defrost Control (A108) Diagnostic LEDs, p.32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977