Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Error Code E182: Outdoor suction temperature sensor fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code E182 on a heat pump means: Outdoor suction temperature sensor fault. It is also called Lennox diagnostic code E182.

Medium severityHeat Pump

Homeowner? What Lennox code E182 means for you

Check, then call Your heat pump is reporting: Outdoor suction temperature sensor fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E182 mean?

Suction temperature sensor reading below 0.25 V or above 4.75 V for 24 h (+/- 3 h); system keeps running normally. S30/S40 thermostat alert code 182 (shown as E182 on the unit control display).

Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E182

  • Failed sensor or wiring
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E182

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
E124Thermostat lost communication to smart hub
E125Control hardware problem
E126Control internal communication problem
E132Device control software fault
E180Outdoor temperature sensor problem
E181Outdoor suction pressure transducer fault
E183Outdoor liquid pressure sensor fault
E184Outdoor liquid temperature sensor fault
E345Relay O failure
E400Compressor internal overload tripped
E401Compressor long run cycle
E402System pressure trip

All Lennox Heat Pump error codes →

Lennox code E182: homeowner questions

What does Lennox code E182 mean?

Outdoor suction temperature sensor fault. Suction temperature sensor reading below 0.25 V or above 4.75 V for 24 h (+/- 3 h); system keeps running normally. S30/S40 thermostat alert code 182 (shown as E182 on the unit control display).

Is it safe to keep using my heat pump with code E182?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code E182 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E182 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E182 near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service