Lennox Error Code 71506: Suction pressure sensor incorrect reading (Heat Pump)
Lennox error code 71506 on a heat pump means: Suction pressure sensor incorrect reading. It is also called Lennox diagnostic code 71506.
Homeowner? What Lennox code 71506 means for you
Usually minor Your heat pump is reporting: Suction pressure sensor incorrect reading. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Lennox error code 71506 mean?
Measured suction pressure (SP) outside expected range; no major system impact. (S40 system diagnostics) S30/S40 thermostat alert code 71506.
Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems
Common causes of Lennox code 71506
- See description
Lennox models that use code 71506
EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060
Other Lennox Heat Pump codes
All Lennox Heat Pump error codes →
Lennox code 71506: homeowner questions
What does Lennox code 71506 mean?
Suction pressure sensor incorrect reading. Measured suction pressure (SP) outside expected range; no major system impact. (S40 system diagnostics) S30/S40 thermostat alert code 71506.
Is it safe to keep using my heat pump with code 71506?
Usually yes. Code 71506 is normally minor, but if it keeps coming back have it checked.
Can I reset Lennox code 71506 myself?
You can try one reset (power off for 30 seconds, then on). If Lennox code 71506 comes back, the cause is still there and a licensed technician should check it.
Who can fix Lennox code 71506 near me?
Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.