Updated · by Aurora Star Tech Inc.

Oil furnace wiring: external relay and bonnet thermostat on a Trane furnace: Oil furnace applications need an external relay. Dual fuel oil applications also need a bonnet thermostat.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Oil furnace and dual fuel oil applications

How to fix oil furnace wiring: external relay and bonnet thermostat: step by step

  1. Wire the external relay as shown in Figure OIL-1.
  2. For dual fuel oil, add the BT bonnet thermostat THT1248 (BAYSEN03ATEMPAA).
  3. For dual fuel oil heat pump systems, cut the JP1 jumper on the control.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

Source: Trane XR402 installer's guide 18-HD29D3-4, p. 9-11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.