Daikin Air Handler: Wiring requirements for field and replacement wire
Wiring requirements for field and replacement wire on a Daikin air handler: Follow these rules when replacing original wiring or making field connections on the EEV cased coil.
Applies to: EEV cased coil and air handler wiring, including fuses F1U and F2U and coil transformer TR1
How to fix wiring requirements for field and replacement wire: step by step
- Replace any original wire with wiring rated at least 105°C.
- Use copper conductors only.
- Ground the unit permanently per N.E.C. and local codes.
- Use N.E.C. Class 2 wire for low voltage.
- Select the transformer supply tap to match the power supply voltage to the gas furnace or blower unit.
- Use manufacturer-specified replacement parts when servicing.
If the unit shows an error code, look it up: Daikin Air Handler codes
More other tips for air handler
Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EA, p. 80. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.