Updated · by Aurora Star Tech Inc.

Front panel shows Operation Prevention in Progress on a Navien heat pump: The heat pump is blocked from running when air or tank water is outside its allowed range. This is normal protection, not a fault.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NWP500 series

Common causes of front panel shows operation prevention in progress

  • Ambient air around the unit is below 41°F (5°C) or above 113°F (45°C).
  • Tank water is below 50°F (10°C) or above 149°F (65°C).

How to fix front panel shows operation prevention in progress: step by step

  1. Check the ambient temperature around the unit.
  2. Check the tank water temperature.
  3. Wait for conditions to return to range; the heat pump resumes automatically.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Heat Pump codes

Source: Navien NWP500 User's Information Manual, p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.