Weil-McLain Boiler: Vent and air pipe requirements
Vent and air pipe requirements on a Weil-McLain boiler: ECO Tec needs direct venting as a Category IV boiler. Use only the vent materials and methods in this manual. Vent and air pipes can be 2 in or 3 in with an adapter for 2 in. Air intake must be 3 in PVC at the adapter. Exhaust must be 3 in PVC, PP or SS at the adapter. All elbows must be sweep elbows, not short-radius. Direct exhaust venting is possible only with the kit option.
Applies to: ECO Tec Series 3 boilers
How to fix vent and air pipe requirements: step by step
- Confirm vent and air pipe size (2 in or 3 in).
- Use a 2 in to 3 in adapter at the boiler for 2 in venting.
- Check that air intake is 3 in PVC and exhaust is 3 in PVC, PP or SS at the adapter.
- Use sweep elbows only.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
More commissioning tips for boiler
Source: ECO Tec Series 3 Condensing Gas Boiler Boiler Manual, p. 184. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.