Weil-McLain Boiler: Tools for troubleshooting
Tools for troubleshooting on a Weil-McLain boiler: Tools recommended for troubleshooting Ultra boilers (Figure 122).
Applies to: Ultra 80, 105, 155, 230, 299, 399
How to fix tools for troubleshooting: step by step
- #2 Phillips screwdriver: remove 4 screws for the top front cover.
- U-Control screwdriver or 1/16 in. flat blade: terminal block wiring.
- 1/8 in. Allen wrench: add orifice when changing natural to propane.
- 7 mm nut driver (155/230/299/399) or #2 Phillips (80/105): change the burner.
- 11 mm nut driver: remove the burner front cover plate.
- 4 mm long Allen wrench: remove the blower from the heat exchanger.
- Multimeter, manometer (incline or digital), combustion analyzer, contact thermometer.
- Keep maintenance kit 383-500-605 (80/105) or 383-500-620 (155/230/299/399) on hand for annual service.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Ultra Series 4 gas-fired water boiler manual, p. 115. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.