Weil-McLain Boiler: Tankless heater application limits
Tankless heater application limits on a Weil-McLain boiler: EG boilers can be ordered with a tankless heater only as factory-installed optional equipment. Standard boilers cannot be adapted. The heater can only be used in a steam boiler or forced hot water system.
Applies to: EG boilers with optional tankless heater
How to fix tankless heater application limits: step by step
- Confirm the boiler was ordered with the factory tankless heater option.
- Install the heater only in a steam boiler or forced hot water system.
- Install the piping as shown in Figure 26 for water boilers or Figure 27 for steam boilers.
- Install an automatic mixing valve per the mixing valve maker's instructions.
- Install a flow regulating valve sized to the heater's intermittent draw from Table 10.
- Install the operating control (small differential recommended) in the temperature control tapping in the heater plate.
- In hard water areas, soften the cold domestic supply to the heater to prevent lime buildup.
- Use brass plugs in tees and crosses to make cleaning easier in hard water areas.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: EG/PEG Series 7 boiler manual, p. 28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.