Updated · by Aurora Star Tech Inc.

Spacing between multiple vent or air terminations on a Weil-McLain boiler: When several Ultra boilers share a wall or roof, each vent and air connection needs its own termination, spaced as below.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Multiple Ultra boilers, direct vent

How to fix spacing between multiple vent or air terminations: step by step

  1. Terminate each vent and air connection separately; do not common vent.
  2. Keep adjacent vent terminations at least 6 inches apart.
  3. Keep adjacent air inlets at least 6 inches apart.
  4. Combustion air piping may be manifolded; vent piping may not.
  5. Build wall penetrations to meet minimum clearances in this manual.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

More other tips for boiler

Source: Ultra Series 4 boiler manual, p. 80-81. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.