Updated · by Aurora Star Tech Inc.

Leak check before starting the boiler on a Weil-McLain boiler: Check for gas odour and gas leaks before and during first start-up. Do not start if a leak is suspected.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All Ultra Series 4 gas boilers

How to fix leak check before starting the boiler: step by step

  1. Use a leak detector or smell near the floor and around the boiler.
  2. Remove the boiler front door and smell inside the enclosure.
  3. Do not proceed if there is any sign of a gas leak; repair it at once.
  4. Check every gas connection with a bubble test and repair any leak before restarting.
  5. Propane only: have the supplier confirm the odorant level before startup and periodically after.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

More commissioning tips for boiler

Source: Weil-McLain Ultra Series 4 boiler manual, p. 37-38. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.