Updated · by Aurora Star Tech Inc.

Circulator load limits: external relay and power needed on a Weil-McLain boiler: Boiler circulators and system circulators above the listed ratings need an external relay and separate power from the boiler.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Boiler and system circulator wiring in multi-boiler layouts

How to fix circulator load limits: external relay and power needed: step by step

  1. Provide an external relay and external power to the boiler circulator if its load exceeds 2.2 A FLA, 3.6 A locked rotor, or 16.4 A inrush.
  2. Provide an external relay and external power to a system circulator if its load exceeds 2.0 A FLA.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

More commissioning tips for boiler

Source: Series 2 Condensing Gas Boiler Advanced Manual, pp. 20-23. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.