Weil-McLain Boiler: Calculate natural gas input from meter
Calculate natural gas input from meter on a Weil-McLain boiler: Measure time for one cubic foot of gas with other appliances off and the boiler running for 10 minutes. Result should be close to the input on the rating label.
Applies to: Ultra Series 4 gas boilers
How to fix calculate natural gas input from meter: step by step
- Run the boiler for 10 minutes.
- Turn off other gas appliances.
- At the gas meter, time how many seconds one cubic foot takes.
- Calculate Btuh = 3600 × 1000 divided by the seconds measured.
- Compare with the input rating on the boiler label.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
More commissioning tips for boiler
Source: Weil-McLain Ultra Series 4 boiler manual, p. 40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.