Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Test equipment needed for start-up

Updated · by Aurora Star Tech Inc.

Test equipment needed for start-up on a Viessmann boiler: Use calibrated equipment only. Needed: multimeter (0-12A, 120V and resistance); flue gas analyzer for CO2 or O2; manometer for gas pressure 0 to 11 in. w.c. (accurate) and up to 28 in. w.c. (a Magnehelic may be used); stack thermometer 0 to 500°F (0 to 260°C); efficiency calculator or tables; CO meter 0 to 400 ppm. Also leak detection fluid approved for natural gas, pipe joint sealant, a garden hose for bleeding and pressure testing, plastic hand brush and rags.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 100-W WB1B start-up and service

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

More other tips for boiler

Source: Viessmann Vitodens 100-W WB1B installation and service manual, p. 53. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.