Remove and reinstall burner assembly on a Viessmann boiler: Burner removal and refit, including gasket replacement and a gas leak test after reassembly. Do not lay the burner on its cylindrical tube or touch the tube mesh, as this can damage it.
Applies to: Vitodens 200-W B2HA
How to fix remove and reinstall burner assembly: step by step
- Switch off the main power and the ON/OFF switch on the boiler control.
- Shut off the gas valve.
- Fold down the control unit and remove the cover.
- Disconnect the cables from the fan motor, gas valve, ionization electrode and ignition module.
- Release the gas supply pipe fitting. Note the gasket between gas valve and fitting.
- Loosen the six Torx T-30 screws and remove the burner.
- Check the burner gasket for damage. Generally replace it every 2 years.
- Refit the burner and tighten the screws in a diagonal pattern to 70 lb.in (8 Nm).
- Fit a new gasket on the gas line connection and tighten to 132 lb.in (15 Nm).
- Reconnect the electrical cables.
- Perform a gas leak test.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 200-W B2HA 112, 150, 399, 530 Service Instructions, p. 24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.