Viessmann Boiler: Read fault history (last 10 faults)

Updated · by Aurora Star Tech Inc.

Read fault history (last 10 faults) on a Viessmann boiler: The control unit stores the 10 most recent faults, including resolved ones, sorted by date. Detailed codes are shown as a sub-code in the fault history.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HB 19 to 35, 68 to 125

How to fix read fault history (last 10 faults): step by step

  1. Press OK and the button symbol shown in the manual at the same time for about 4 seconds.
  2. Select 'Fault history'.
  3. Select 'Display?'.
  4. Press OK to show the fault code. Look up the code in the fault code tables.
  5. For some faults, the type of fault is also shown in plain text.
  6. After servicing, select code 24:0 to reset the service-required indication (code 0F).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

B2HB 45B2HB 45, 160B2HB 57B2HB 57, 199B2HB 160B2HB 199

More service & test modes tips for boiler

Source: Vitodens 200-W B2HB service instructions, p. 75. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.