Viessmann Boiler: Jumper pin must be removed for on-demand DHW via CombiPLUS
Jumper pin must be removed for on-demand DHW via CombiPLUS on a Viessmann boiler: If the X8 jumper pin is left in place, the boiler will not provide on-demand hot water through the CombiPLUS. If the jumper is removed but the CombiPLUS is not programmed, DHW falls back to the built-in resistors in the power pump module.
Applies to: Vitodens 100-W WB1B with CombiPLUS
How to fix jumper pin must be removed for on-demand dhw via combiplus: step by step
- Remove the X8 jumper pin.
- Program the boiler for CombiPLUS use (see programming, p. 35).
If the unit shows an error code, look it up: Viessmann Boiler codes
More commissioning tips for boiler
Source: Vitodens 100-W WB1B installation and service instructions, p. 31. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.