Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Check control unit fuse F4

Updated · by Aurora Star Tech Inc.

Check control unit fuse F4 on a Viessmann boiler: Check the fuse on the control unit.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Control unit fuse F4 T 2.5A

How to fix check control unit fuse f4: step by step

  1. Switch off the main power supply.
  2. Flip down the control unit.
  3. Remove cover A.
  4. Check fuse F4, T 2.5A slow blow.
  5. Replacement fuses come from Viessmann in packs of 10 (Part No. 7404 396).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

WB1AWB1B

Source: Vitodens 100-W, WB1B CombiPlus Installation & Service, p. 81. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977