Viessmann Boiler: Change the heating curve slope and shift

Updated · by Aurora Star Tech Inc.

Change the heating curve slope and shift on a Viessmann boiler: Done from the extended menu under the heating circuit selection.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 200-W B2HB heating circuits

How to fix change the heating curve slope and shift: step by step

  1. Call up the extended menu.
  2. Select Heating, press OK, then select the heating circuit.
  3. Accept with OK, then select Heating curve and press OK.
  4. Select Slope or Shift and press OK, change the value, and select the curve matching the system.
  5. Exit the menu.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Models

Vitodens 200-W B2HB 45Vitodens 200-W B2HB 57Vitodens 200-W B2HB 160Vitodens 200-W B2HB 199

More settings shortcuts tips for boiler

Source: Vitodens 200-W B2HB service instructions, p. 39. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.