Viessmann Boiler: Carbon monoxide detector and gas vent signage (Massachusetts)
Carbon monoxide detector and gas vent signage (Massachusetts) on a Viessmann boiler: Applies to side-wall horizontally vented gas equipment in residential buildings where the vent terminal is less than 7 ft above finished grade.
Applies to: Vitodens 200-W B2HA 19, 28, 35 on Massachusetts installations
How to fix carbon monoxide detector and gas vent signage (massachusetts): step by step
- Confirm a hard-wired CO detector with alarm and battery backup is installed on the floor level where the boiler is located.
- Confirm a battery-operated or hard-wired CO detector with alarm is installed on each additional level served.
- If the boiler is in a crawl space or attic, the hard-wired detector may be on the next adjacent floor level.
- If the requirement cannot be met at completion, the owner has 30 days. A battery-operated CO detector with alarm must be installed in the meantime.
- Use CO detectors that meet NFPA 720, are ANSI/UL 2034 listed and IAS certified.
- Mount a metal or plastic sign on the building exterior at least 8 ft above grade, directly in line with the vent terminal. Lettering must be at least 1/2 in. and must state the gas vent is directly below and to keep the area clear of obstructions.
- Note that the state or local gas inspector will not approve the installation without the detectors and sign.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Vitodens 200-W B2HA service instructions, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.