Viessmann Boiler: Burner shuts off below set-point and restarts repeatedly (cycling)
Burner shuts off below set-point and restarts repeatedly (cycling) on a Viessmann boiler: Burner switches off while boiler water is still below the set-point and then restarts again.
Applies to: Vitodens 100-W WB1B
Common causes of burner shuts off below set-point and restarts repeatedly (cycling)
- Flue gas system leakage (flue gas recirculation)
- Incorrect running gas pressure
How to fix burner shuts off below set-point and restarts repeatedly (cycling): step by step
- Check the flue gas system for leakage (flue gas recirculation).
- Check the running gas pressure.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Source: Vitodens 100-W WB1B installation and service instructions, p. 74. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.