Rinnai Boiler: Venting general guidelines

Updated · by Aurora Star Tech Inc.

Venting general guidelines on a Rinnai boiler: Direct vent or non-direct vent (room air) are both allowed. Non-direct vent must use Category IV vent of a type listed by a recognised testing agency. Exhaust must always go straight outside. Keep the vent as direct as possible with few fittings, press manufactured joints fully together for an airtight seal, and use only approved sealant, primer or glue. Support horizontal runs about every 4 ft and vertical runs about every 6 ft, or per vent maker or local code. Avoid sags. Reused venting must be inspected and any damaged parts replaced before operation. Do not use cellular core PVC/CPVC, Radel, ABS or galvanised pipe. Do not insulate non-metal vent pipe. Do not mix vent components from different manufacturers. Do not reduce the vent below 2 in. diameter. Do not connect to an existing vent or chimney, and do not common vent with another appliance. Warranty does not cover vent installation problems.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All I-Series Plus venting

How to fix venting general guidelines: step by step

  1. Confirm the venting option (direct or non-direct) and the vent material is approved for this boiler.
  2. Keep runs short and direct, with a minimum of fittings.
  3. Support horizontal runs every 4 ft and vertical runs every 6 ft, or per manufacturer or code.
  4. Replace any damaged vent components before operating the boiler.
  5. Do not use cellular core PVC/CPVC, Radel, ABS, galvanised pipe or insulation on non-metal vent.
  6. Do not mix manufacturers, reduce diameter below 2 in., or connect to an existing chimney.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.