Rinnai Boiler: Turn gas on or off to the appliance
Turn gas on or off to the appliance on a Rinnai boiler: The boiler has no pilot. It uses direct ignition and lights the burner automatically. The manual gas valve at the inlet is turned by hand only.
Applies to: Manual gas shutoff valve at boiler inlet
Common causes of turn gas on or off to the appliance
- Gas leak or unsafe ignition if steps are skipped
How to fix turn gas on or off to the appliance: step by step
- Set the temperature controller to its lowest setting.
- Turn off all electric power to the appliance if service is needed.
- Turn the manual gas valve at the boiler inlet clockwise to OFF.
- To restore gas, wait five minutes to clear any gas, then smell near the floor for gas. If gas is smelled, stop and follow the gas leak procedure.
- Turn the manual gas valve counterclockwise to ON by hand only. Do not use tools.
- Turn on electric power and set the temperature controller to the desired setting.
- If the boiler will not run, turn the gas off again and call a service technician.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation manual, p. 48. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.