Updated · by Aurora Star Tech Inc.

Test the condensate pump safety switch on a Rinnai boiler: Confirms the boiler faults when the reservoir float closes the circuit and clears once the pump runs again. The switch is normally open and faults when it closes.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: I-Series Plus condensing combi boilers with a condensate pump

Common causes of test the condensate pump safety switch

  • Condensate reservoir full, float switch closed

How to fix test the condensate pump safety switch: step by step

  1. Unplug the condensate pump.
  2. Fill the condensate reservoir with water until the float switch closes.
  3. Turn the boiler on. Expect diagnostic code 250.
  4. Plug the pump back in and confirm condensate is leaving the reservoir.
  5. Press the On/Off button to turn the boiler off, wait 5 seconds, then turn the power back on to clear code 250.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

Source: Rinnai I-Series Plus IP060160C installation manual, p. 65. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.