Updated · by Aurora Star Tech Inc.

Set up DHW recirculation through the PC board on a Rinnai boiler: Enables and configures the DHW recirculation function using the left PC board button.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: I-Series Plus Condensing Combi Boiler

How to fix set up dhw recirculation through the pc board: step by step

  1. Remove the boiler front panel and locate the PC board at the lower left side of the unit.
  2. Locate the left PC board button.
  3. Press and hold the button for five seconds to enter parameter setting.
  4. Set parameter 09 to b (YES) to enable DHW recirculation.
  5. Set parameters 12, 13 and 20 to the required settings for the piping and controls.
  6. Replace the front panel.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 102. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.