Rinnai Boiler: Monthly owner maintenance checks
Monthly owner maintenance checks on a Rinnai boiler: Monthly checks for area, piping, venting and boiler condition.
Applies to: I-Series Plus combi boiler
How to fix monthly owner maintenance checks: step by step
- Confirm the area is free of combustibles, gasoline and flammable vapors, and is clean and unobstructed.
- Confirm the air intake area has no contaminants.
- Inspect water, gas and condensate piping for leaks, corrosion or signs of leaking lines.
- Confirm the condensate line is not blocked; if a condensate pump is used, confirm it works.
- Confirm the vent discharge and air intake are clear, and check vent for leaks, damage or deformation.
- Confirm there are no fault codes, loud noises or leaks on the boiler.
- Confirm the pressure on the controller or external gauge reads 17 to 26 PSI (117 to 180 kPa).
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 115. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.