Rinnai Boiler: Glycol antifreeze check
Glycol antifreeze check on a Rinnai boiler: Use only glycol formulated for hydronic use with multi-metal inhibitors. Maximum allowed concentration is 40 percent. Test the fluid at least once a year.
Applies to: All I-Series Plus condensing combi boilers
Common causes of glycol antifreeze check
- Glycol concentration too high or inhibitor level too low
How to fix glycol antifreeze check: step by step
- Use only an approved antifreeze from the approved list.
- Test the system fluid for glycol concentration and inhibitor level at least once a year.
- Keep the glycol concentration at or below 40 percent.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus Condensing Combi Boiler Manual, p. 121. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.