Rinnai Boiler: Fill the condensate collector before operation and before venting
Fill the condensate collector before operation and before venting on a Rinnai boiler: The condensate collector must be filled with water before the boiler runs and before the vent system is installed, otherwise exhaust gas can enter the building. Failure to fill it can cause severe injury or death.
Applies to: I-Series Plus before first start and venting
How to fix fill the condensate collector before operation and before venting: step by step
- Pour approximately 10 oz (1.25 cups) of water directly into the boiler exhaust port.
- Do this with the 2 in. PVC adapter still fitted to the exhaust port.
- Complete this before installing the vent system.
If the unit shows an error code, look it up: Rinnai Boiler codes
More commissioning tips for boiler
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.