Rinnai Boiler: Enable simultaneous central heating and domestic hot water

Updated · by Aurora Star Tech Inc.

Enable simultaneous central heating and domestic hot water on a Rinnai boiler: By default the boiler gives domestic hot water priority. Simultaneous operation divides flow between the DHW plate heat exchanger and the central heating circuit.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: I-Series Plus Condensing Combi Boiler

How to fix enable simultaneous central heating and domestic hot water: step by step

  1. Remove the front panel by removing the two screws.
  2. Locate the PC board and the left PC board button.
  3. Press and hold the button for five seconds.
  4. Set parameter 08 to b to enable simultaneous central heating and DHW.
  5. Set parameter 14 and 15 as required (see the simultaneous operation setting).
  6. Confirm the central heating system is designed for the higher supply temperature if parameter 14 is set to b.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 103. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.