Rinnai Boiler: Crossover mode recirculation setup
Crossover mode recirculation setup on a Rinnai boiler: Uses the cold water line for hot water recirculation. Requires a thermal bypass valve at the furthest fixture.
Applies to: I-Series Plus Condensing Combi Boiler
How to fix crossover mode recirculation setup: step by step
- Install one thermal bypass valve at the furthest fixture in the plumbing system.
- Do not install more than one thermal bypass valve in the system.
- Use only for Crossover mode systems.
- Note that the minimum DHW setpoint becomes 116°F (47°C) in crossover mode.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 99. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.