Rinnai Boiler: Choose a venting option (direct vent or non-direct vent)
Choose a venting option (direct vent or non-direct vent) on a Rinnai boiler: Direct vent uses concentric pipe, where exhaust exits the inner pipe and combustion air enters the outer pipe, or twin pipe, with separate air and exhaust penetrations. Non-direct vent (room air) takes combustion air from the room and vents exhaust outside. For direct vent, use only the approved vent manufacturers and products listed in section 5.5.1.
Applies to: I-Series Plus venting
How to fix choose a venting option (direct vent or non-direct vent): step by step
- Select direct vent concentric or twin pipe, or non-direct vent (room air).
- For direct vent, pick components only from the approved manufacturer list in section 5.5.1.
- For non-direct vent, confirm room air volume meets the national fuel gas code, CSA B149.1, or local building code.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.